Syllabus Edition

First teaching 2023

First exams 2025

|

Production & Use of X-rays (CIE A Level Physics)

Topic Questions

1a
Sme Calculator
1 mark

In an X-ray tube, charged particles are accelerated towards a metal target by an applied potential difference.

State the name of the charged particles that are accelerated by the applied potential difference.

1b
Sme Calculator
10 marks

Fig. 1.1 shows a simplified diagram of an X-ray tube.

24-1-3a-e-24-1-e-structure-of-an-x-ray-tube-cie-ial-sq

Fig. 1.1

State the name and purpose of
 
(i)
Component A
[2]
(ii)
Component B
[2]
(iii)
Component C
[2]
(iv)
Component D
[2]
(v)
Component E
[2]
1c
Sme Calculator
2 marks

Explain how X-rays are produced at the metal target.

1d
Sme Calculator
4 marks

The accelerating potential difference between the cathode and the anode of an X-ray tube is 75 kV.

(i)
State the maximum energy, in eV, of the photons produced in the X-ray tube.
[1]
(ii)
Calculate the minimum wavelength of photons in the X-ray beam.
[3]

Did this page help you?

2a
Sme Calculator
4 marks
(i)
Explain what is meant by ionising radiation and why it can be harmful.
[2]
(ii)
Place ticks () next to the scans in Table 1.1 which use ionising radiation.
 
Table 1.1
Type of scan  
X-ray Imaging  
Ultrasound  
PET scan  
CT scan  
[2]
2b
Sme Calculator
1 mark

The attenuation of a parallel beam of X-ray radiation is given by the expression

I over I subscript 0 space equals space e to the power of negative mu x end exponent

State the meaning of the term attenuation.

2c
Sme Calculator
3 marks

Table 1.1 shows the linear absorption coefficient μ for an X-ray beam in blood and in muscle.

Table 1.1

  μ / cm−1
blood 0.23
muscle 0.22

 

(i)
State what is meant by the contrast of an X-ray.
[1]
(ii)
Using the data in Table 1.1, explain why an X-ray image of blood vessels in muscle would have poor contrast.
[2]
2d
Sme Calculator
3 marks

Describe the differences between CT scanning and X-ray imaging.

Did this page help you?

3a
Sme Calculator
2 marks

A parallel beam of X-rays is incident on a medium with a linear absorption coefficient μ.

State what is meant by the linear absorption coefficient.

3b
Sme Calculator
2 marks

Describe the difference between sharpness and contrast in X-ray imaging.

3c
Sme Calculator
2 marks

State two causes of the loss of sharpness of an X-ray image.

3d
Sme Calculator
4 marks

State

(i)
what is meant by the hardness of an X-ray beam
[2]
(ii)
how the hardness of the X-ray beam is controlled.
[2]

Did this page help you?

1a
Sme Calculator
3 marks

The data in Table 1.1 shows how the attenuation coefficient μ depends on the energy of the X-rays in bone and muscle. 

Table 1.1

maximum X-ray energy / keV mu subscript b o n e end subscript / cm−1 mu subscript m u s c l e end subscript / cm−1
50 3.32 0.54
100 0.60 0.21
250 0.32 0.16
4000 0.087 0.049

Using the data in Table 1.1, state and explain which X-ray energy would produce an image of a bone next to a muscle with the best contrast.

1b
Sme Calculator
6 marks

For X-ray energies around 30 keV and below, the attenuation coefficient μ is approximately proportional to the cube of the proton number Z of the absorbing material.

The proton numbers of muscle, bone and some contract media are shown in Table 1.2

Table 1.2

substance main elements  
muscle  straight H presubscript 1straight C presubscript 6straight O presubscript 8  
bone  straight H presubscript 1straight C presubscript 6straight O presubscript 8straight P presubscript 15Ca presubscript 20  
contrast media  straight I presubscript 53Ba presubscript 56  

 

Using the information in Table 1.2

(i)
Show that bone absorbs X-rays about eight times more strongly than muscle.
[3]
(ii)
Explain why contrast media are made from elements with high values of atomic number Z.
[3]
1c
Sme Calculator
4 marks

The graph in Fig. 1.1 shows how the attenuation coefficient μ of muscle varies with photon energy E.

24-1-2c-h-24-1-h-attenuation-xray-energy-cie-ial-sq

Fig. 1.1

Using Fig. 1.1, explain why X-rays with energies less than 20 keV are usually filtered out of the beam.

1d
Sme Calculator
3 marks

An X-ray beam of energy 20 keV and intensity I subscript 0 is incident on a sample of muscle and bone as shown in Fig. 1.2. The emergent beam intensities from the muscle and bone are I subscript m and I subscript b respectively.

24-1-2d-h-24-1-h-muscle-bone-xray-comparison-cie-ial-sq

Fig. 1.2

Using the graph in Fig. 1.1, calculate the ratio of intensities to compare the attenuation produced by 1 cm of bone and 1 cm of muscle.

Did this page help you?

2a
Sme Calculator
6 marks

An ultrasound investigation was used to identify a small volume of an unknown substance in a patient. It is suspected that this substance is either a cyst or a tumour.

During the ultrasound investigation, an ultrasound pulse of frequency 5 MHz is passed through soft tissue and then into the small volume of the unknown substance.

The ratio of the reflected intensity to the incident intensity for the ultrasound pulse reflected at the boundary was found to be 7.54 × 10−5.

Table 1.1 shows some information about the density and speed of ultrasound in soft tissue, cysts and tumours.

Table 1.1

material density / kg m−3 ultrasound velocity / m s−1
soft tissue 1065 1530
cyst 1020 1570
tumour 990 1565

(i)
Use the information in Table 1.1 to show that the unknown medium is a cyst.
[4]
(ii)
A pulse of ultrasound reflected from the front surface of the cyst was detected 27.5 µs later and a pulse from the rear surface was detected 43.2 µs later.
 
Determine the length of the cyst, in cm.
[2]
2b
Sme Calculator
3 marks

Fig. 1.1 shows a beam of X-rays of energy 20 keV incident normally on some soft tissue which contains the cyst.

The cyst is located 2.1 cm from the surface of the soft tissue.

24-1-3b-h-24-1-h-x-ray-intensity-cyst-cie-ial-sq

Fig. 1.1 (not to scale)

The attenuation constant of the soft tissue is 0.85 cm–1. The incident intensity of the beam is 4.6 × 103 W m–2.

The X-ray beam is switched on for a time t.

Determine the energy of the X-ray beam incident on the front surface of the cyst each second. State any assumptions you make.

2c
Sme Calculator
5 marks

The ratio of the intensities of the emergent X-ray beams X and Y is determined to be

I subscript Y over I subscript X space equals space 0.94

(i)
Determine the attenuation coefficient of the cyst.
[3]
(ii)
Compare the quality of the images that would be obtained from the ultrasound and the X-ray scans of the cyst.
[2]
2d
Sme Calculator
3 marks

Suggest a different imaging technique that could be used to image the cyst. Explain one advantage and one disadvantage of using this technique over ultrasound.

Did this page help you?

1
Sme Calculator
3 marks
(i)
State what is meant by contrast in an X-ray image.

[1]

(ii)
A parallel beam of X-ray radiation is incident, separately, on samples of bone and of muscle.

Data for the thickness x of the samples of bone and of muscle, together with the linear attenuation coefficients μ of the radiation in bone and in muscle, are given in Table 10.1.

Table 10.1

  x / cm μ / cm–1
bone 1.5 2.9
muscle 4.0 0.95

Calculate the ratio

fraction numerator space intensity space of space radiation space transmitted space through space the space bone space over denominator intensity space of space radiation space transmitted space through space the space muscle end fraction.




ratio = ........................................ [2]

Did this page help you?

2a
Sme Calculator
5 marks
(i)
Explain how X-rays are produced for use in medical diagnosis
[3]
 
(ii)
Discuss one advantage and one disadvantage of using CT scanning over X-ray imaging.
[2]
2b
Sme Calculator
4 marks

An X-ray image is taken of the skull of a patient. Another patient has a CT scan taken of their entire head.

Describe how the image produced during CT scanning differs from the image produced by X-ray imaging.

Did this page help you?

3a
Sme Calculator
4 marks

Two patients arrive at a hospital. One patient is a child with a broken arm, the other is a pregnant woman coming in for a check-up for her unborn foetus.

Over the course of the diagnosis and treatment of the child’s broken arm, several images of the arm are required.

Similarly, to check the progress of a woman’s pregnancy, several images of the foetus are required.

For each scenario, suggest the most appropriate imaging technique to use and give two reasons for the choice.

3b
Sme Calculator
6 marks

An X-ray image showing the cross-section of the bone and muscle is shown in Fig. 1.1.

24-1-3d-m-24-1-xray-bone-muscle-diagram-cie-ial-sq

Fig. 1.1

Parallel X-ray beams of intensity I subscript 0 are incident on the muscle and bone as shown. The emergent beam after passing through muscle alone has an intensity of I subscript m and an intensity of I subscript b m end subscript after passing through the bone and the muscle.

(i)
Determine, in terms of I subscript 0, the intensities I subscript m and I subscript b m end subscript of the emergent X-rays.
 
The linear attenuation coefficient of bone is 2.90 cm−1

The linear attenuation coefficient of muscle of 0.95 cm−1.

[4]

(ii)
Suggest why, on an X-ray plate, the contrast between bone and muscle is much greater than the contrast between fat and muscle.
 
The linear attenuation coefficient of fat is 0.90 cm−1.
[2]

Did this page help you?