IB Physics SL

Revision Notes

7.1.9 Investigating Half-Life

Investigating Half-Life

Aim of the Experiment

  • The aim of the experiment is to investigate the half-life of a decaying radioactive sample
    • This can be done with a live sample if safe access is available
    • This can also be done through an online simulation

Variables

  • Independent variable = time, t
  • Dependent variable = radioactive activity, A
  • Control variables:
    • Size of sample
    • Same distance from detector to sample
    • Same material for sample

Equipment List 

 

  • Resolution of equipment:
    • Metre ruler = 1 mm
    • Stopwatch = 0.01 s

Method 

  1. Measure the background radiation for 30 second intervals using a Geiger-Muller tube without the radiation source in the room, take several readings and find an average
  2. Next, put the radiation source at a set starting distance appropriate for the ionizing strength of the radiation (e.g. 1 – 2 cm for an alpha source, 2 – 5 cm for a beta source and 15 – 30 cm for a gamma source) from the GM tube
  3. If graphing software is available to use with the Geiger-Muller tube, then that should be started as soon as the source is placed in position, if not, then proceed to step 4
  4. Once the sample is in place measure the number of counts in 30-second intervals for 10 minutes or until the activity greatly decreases from the beginning value
  5. Remove sample and replace into a lead-lined box or safe storage container
  6. Repeat this for several trials if possible using fresh same size samples

A suitable table of results might look like this:

Analysis of Results 

  • What is important for this experiment is the initial count rate and the following decrease as the radioactive source decays from the parent nuclei into the daughter nuclei.
    • The background rate must be subtracted from the data before analysis can begin. This is true for both graphed and manual data
  • In order to see the decrease and model it, the data should be graphed with the correct count rate (background subtracted) on the y-axis and the time intervals on the x-axis. If graphing software is used then the graph should look similar to the following:

Radioactivity Fluctuations, downloadable AS & A Level Physics revision notes

  • However, if the manual method is used, then there will be twenty data points rather than a smooth curve with fluctuations
  • Using this curve, the half-life can be found by comparing the initial magnitude of the activity with the time it takes to decay to half of the original activity.
    • This can be extended by finding the time taken for two half-lives to pass and the activity to reach one quarter for quantitative comparison

Half-life Graph, downloadable IGCSE & GCSE Physics revision notes

  • Compare found half-life for the radioactive sample with the known value

Evaluation

Systematic errors:
  • The Geiger counter may suffer from an issue called “dead time”
    • This is when multiple counts happen simultaneously within ~100 μs and the counter only registers one
    • This is a more common problem in older detectors, so using a more modern Geiger counter should reduce this problem
  • If this experiment is done manually, there will be uncertainty in the time
    • This uncertainty in time intervals will mean variation in counting intervals, however, due to the 30-second interval and the nature of this experiment this is not easily accounted for
    • It is best to discuss what these uncertainties could mean for the results of this experiment
Random errors:
  • Radioactive decay is random, so repeat readings are vital in this experiment
  • Measure the count over an appropriate time span such as 30 seconds
    • A larger count helps reduce the statistical percentage uncertainty inherent in smaller readings
    • This is because the percentage error is proportional to the inverse-square root of the count
    • However, a shorter count will mean that more data points are available to help make an appropriate decay curve

Safety Considerations

  • For any radioactive source:
    • Reduce the exposure time by keeping it in a lead-lined box when not in use
    • Handle with long tongs
    • Avoid physical contact and handle the source with care
    • Do not point the source at anyone and keep a large distance (as activity reduces by an inverse square law)
  • Safety clothing such as a lab coat, gloves and goggles must be worn

Worked Example

A student measures the background radiation count in a laboratory and obtains the following readings:

 

The student is trying to verify the half-life of a sample of Barium-137. He collects the following data:

 

Use this data to determine the half-life of the radioactive samples.

Step 1: Determine a mean value of background radiation

 

Step 2: Calculate C (corrected average count rate)

 

Step 3: Plot a graph of C against t (time in 30-sec intervals) and add a smooth-fitting curve

 

Step 4: Map the first three half-lives use the curve

  • The first half-life took approximately 160 seconds to occur
  • The second half-life took approximately 150 seconds to be reached following the first half-life
  • The third half-life took approximately 155 seconds to be reached following the second half-life

Step 5: Average the half-lives

(160 + 150 + 155) ÷ 3 = 155 seconds

Step 6: State the final answer

  • The final found answer was 155 seconds for the half-life of this sample data

 

Close

Join Save My Exams

Download all our Revision Notes as PDFs

Try a Free Sample of our revision notes as a printable PDF.

Join Now
Already a member?